Title 24 Compliance for Custom Steel Windows and Doors

2025 California Energy Code

PINKYS Custom Studio Steel thermally broken assemblies are designed and NFRC certified to meet 2025 Title 24 Part 6 prescriptive requirements across California's 16 climate zones, on both the prescriptive and performance compliance paths.

Studio Steel thermally broken fixed windows achieve whole-unit U-factors as low as 0.21. The 2025 code's residential prescriptive maximum is 0.27 in most California climate zones and 0.30 in Climate Zones 6-10 and 15, meaning the lowest-U Studio Steel configurations meet the maximum in every zone. Higher-U configurations within the certified range require zone-specific configuration selection.

California is PINKYS' home market, and the 2025 Energy Code is the most stringent fenestration standard in the US.

Prescriptive Max U-Factor

0.27-0.30

(2025 code, by zone)

Studio Steel Low

0.21

(TB fixed window, triple pane)

SHGC Range

0.13-0.22

(SB70 configurations only)

Air Leakage

<=0.3 cfm/ft²

for all rated assemblies

16 CLIMATE ZONES — Prescriptive Compliance, 2025 Residential

ZoneCitiesMax U / SHGCCompliance PathNotes
1Arcata, Blue Lake0.27 / NonePrescriptive or PerformanceNo SHGC limit. Triple pane SB70 (U 0.21) meets the U max. Dual pane SB70 (U 0.30) does not - use triple pane for prescriptive, or dual pane on performance.
2Sacramento, Napa0.27 / 0.23Prescriptive or PerformanceTriple pane SB70 (U 0.21, SHGC 0.15) meets both. Dual pane SB70 (U 0.30, SHGC 0.22) meets SHGC but exceeds U threshold - triple pane needed for prescriptive.
3Oakland, San Francisco0.27 / NonePrescriptive or PerformanceNo SHGC limit. Same as Zone 1 - triple pane meets, dual pane needs performance path.
4San Jose, Santa Rosa0.27 / 0.23Prescriptive or PerformanceSame pattern as Zone 2 - triple pane SB70 meets both.
5Santa Monica, Long Beach coast0.27 / NonePrescriptive or PerformanceNo SHGC limit. Triple pane (U 0.21) meets the U max.
6Los Angeles, San Diego coast0.30 / 0.23Prescriptive or PerformancePINKYS home climate zone. Full certified range (0.21-0.30) qualifies - either config meets prescriptive.
7San Diego inland, Chula Vista0.30 / 0.23Prescriptive or PerformanceFull certified range qualifies. Cooling load dominant; SB70 Low-E recommended.
8Los Angeles, Pasadena0.30 / 0.23Prescriptive or PerformanceFull certified range qualifies. Significant cooling load; SB70 essential.
9Anaheim, West Covina0.30 / 0.23Prescriptive or PerformanceFull certified range qualifies. Significant cooling load; Low-E specification critical.
10Riverside, San Bernardino0.30 / 0.23Prescriptive or PerformanceFull certified range qualifies. Triple pane (SHGC 0.15) provides additional margin.
11Redding, Marysville0.27 / 0.23Prescriptive or PerformanceTriple pane SB70 meets both - needed for prescriptive; dual pane exceeds U threshold.
12Sacramento metro0.27 / 0.23Prescriptive or PerformanceSame pattern as Zone 11.
13Fresno, Bakersfield0.27 / 0.23Prescriptive or PerformanceSame pattern as Zone 11. Extreme summer heat.
14Lancaster, Victorville0.27 / 0.23Prescriptive or PerformanceSame pattern as Zone 11. Widest diurnal swings in state.
15Palm Springs, El Centro0.30 / 0.20Prescriptive or PerformanceSHGC max is 0.20 here, not 0.23. Dual pane SB70 (0.22) no longer meets SHGC. Triple pane (0.21/0.15) meets both - required for prescriptive here.
16Big Bear, Mammoth0.27 / NonePrescriptive or PerformanceNo SHGC limit. Triple pane (U 0.21) meets the U max; heating-dominated zone benefits from triple pane regardless.

Source: 2025 California Energy Code, Title 24 Part 6, Table 150.1-A (residential, single-family).

Every zone has a certified SB70 configuration that meets the prescriptive path. In the 10 zones capped at 0.27 (all except CZ 6-10 and 15), that means specifying the triple pane configuration specifically - dual pane still works, but only via the performance path in those zones. In CZ 6-10 and 15 (capped at 0.30), the full certified range qualifies for prescriptive, though Zone 15's tighter SHGC max (0.20) still narrows the field to triple pane there too.

Title 24 is shorthand for the California Code of Regulations, Title 24, specifically Part 6, the California Energy Code, administered by the California Energy Commission (CEC). It sets minimum energy efficiency standards for new construction and significant alterations across all building types in California. The current operative version is the 2025 Energy Code, which took effect January 1, 2026 and applies to any project with a permit application dated on or after that date.

For fenestration (windows, doors, skylights, and glazed assemblies), Title 24 Part 6 establishes mandatory minimum performance requirements for U-factor, SHGC, and air leakage. Requirements vary by climate zone, building type, and compliance path. NFRC-certified values are the required input for both compliance paths.

Steel is approximately three times stiffer than aluminum, achieving the same structural performance at a fraction of the profile depth. Narrower profiles mean more glass area per opening. The thermal break, a non-conducting polyamide isolator, closes the thermal gap with aluminum. With it, Studio Steel certified U-factors reach 0.21 on fixed windows, meeting the prescriptive maximum in every zone at the low end of the certified range.

The CEC updates Title 24 on a roughly triennial cycle. The 2025 code took effect January 1, 2026, superseding the 2022 code's flat 0.30 U-factor maximum. Documentation referencing the 2022 code's uniform 0.30 threshold is now outdated.

Prescriptive Path

Each individual fenestration product must meet the code's specified U-factor and SHGC maximums for its climate zone. No whole-building energy model required. For thermally broken fixed windows, the lowest-U configuration (0.21) meets every zone; configurations toward the top of the certified range (up to 0.30) meet only Climate Zones 6-10 and 15.

Performance Path

The entire building is evaluated using CEC-approved energy modeling software (CBECC-Res residential, EnergyPro nonresidential). Individual products don't need to meet prescriptive maximums in isolation. Studio Steel provides complete NFRC data for energy modeling input. Compliance analysis is the responsibility of the project's licensed Title 24 analyst.

U-Factor

Whole-unit rate of heat transfer through the complete assembly, BTU/hr-ft2-F. Lower is better. 2025 residential prescriptive max: 0.27 in most zones, 0.30 in Climate Zones 6-10 and 15. Studio Steel fixed windows achieve as low as 0.21.

SHGC

Fraction of solar radiation admitted as heat. Confirmed against the 2025 code (Table 150.1-A): 0.23 in most zones, not required in Zones 1, 3, 5, and 16, and a tighter 0.20 in Zone 15 - the only zone where the 2025 cycle lowered the threshold below 0.23. SB70 dual pane achieves SHGC 0.22; SB70 triple pane achieves SHGC 0.15.

VT (Visible Transmittance)

Proportion of visible light transmitted. Title 24 does not mandate a minimum VT, though it factors into daylighting credits under the performance path.

Air Leakage

Confirmed against the 2025 code (Section 110.6(a)1): flat 0.3 cfm/ft2 for windows and residential doors - no operable/fixed split. Matches Studio Steel's current NFRC chart. Nonresidential double swinging doors specifically: 1.0 cfm/ft2 (not applicable to Studio Steel's standard line).

COMPLIANCE STATUS

Thermally broken assemblies only, SB70 glazing configurations.
Prescriptive residential maximum (windows/glazed doors, per Table 150.1-A): U 0.27 (most zones) / U 0.30 (Climate Zones 6-10, 15).
SHGC 0.23 in most zones, NR in Zones 1/3/5/16, 0.20 in Zone 15.

ProductU-factor Range (SB70)SHGC Range (SB70)Compliance Path
TB fixed windows0.21-0.300.15-0.22Prescriptive or Performance - triple pane meets every zone; dual pane meets CZ 6-10, 15 outright and needs performance path elsewhere
TB casement windows0.31-0.380.13-0.19Performance Only - best configuration (0.31) exceeds even the most permissive residential threshold (0.30)
TB swing doors0.26-0.350.13-0.20Prescriptive or Performance - triple pane (U 0.26) meets every zone; dual pane (U 0.35) needs performance path everywhere
All other TB productsContact PINKYSContact PINKYSContact PINKYS for configuration-specific compliance path
Solid steel, non-TB (Fixed Window SDL/TDL, Swing Door SDL/TDL)0.41-0.740.20-0.48Performance Only - best-case configuration (0.41) still exceeds every residential prescriptive threshold

All figures are whole-unit NFRC values for confirmed SB70 configurations.

Full certified product tables here -->

NONRESIDENTIAL PRESCRIPTIVE — Table 140.3-B

Product typeMax U-factorMax RSHGCMin VTCompliance Path
Fixed window0.36 (Zones 1-8,10,16) / 0.34 (9,11-15)0.25 (1-8,10,16) / 0.22 (9,11-15)0.42Prescriptive or Performance - TB fixed window range (0.21-0.30) clears every zone with margin
Curtainwall / storefront0.38 (Zones 1,7) / 0.41 (all other)0.25 (1,7) / 0.26 (all other)0.46Contact Studio Steel
Operable window0.46 all zones0.22 all zones0.32Prescriptive or Performance - TB casement range (0.31-0.38) clears every zone
Glazed doors0.45 all zones0.23 all zones0.17Prescriptive or Performance for TB swing doors (0.26-0.35, both configs clear); Performance Only for non-TB swing doors (0.53-0.74)

Source: Title 24 2025

Max WWR: 40% all climate zones, all nonresidential building types.

Confirmed against the 2025 code: for residential (single-family) prescriptive path, the cap is 20% of conditioned floor area (CFA) for total fenestration, with an additional 5% CFA cap on west-facing area in most zones (not required in Zones 1, 3, 5, and 16). For nonresidential, the WWR cap is a flat 40% across all climate zones.

A Studio Steel thermally broken frame achieves the same structural performance as a wider aluminum frame at a fraction of the profile depth, meaning more glass area within the same WWR budget. Pair that with the correct Low-E tier and glazing configuration for the zone and orientation, and the result is a large glazed design that meets Title 24 without design compromise - even under the tighter 0.27 threshold now in effect across most of the state.

Prescriptive path: NFRC Certified Label ships with each assembly - the primary compliance documentation accepted by California building departments. Additional documentation available on request: product-specific certified values, climate zone compliance confirmation, and CF1R/CF2R form support.

Performance path: Complete product performance data (U-factor, SHGC, VT, air leakage, frame area, glazing area) in CBECC-Res / EnergyPro input format. Performance path compliance analysis is the responsibility of the project's licensed Title 24 analyst.

Contact PINKYS at specification stage with project climate zone, building type, and compliance path. Lead time is 12 to 15 weeks from approved shop drawings.

bright and airy luxury bedroom featuring full-width arch top double doors with side windows and kickplate
DArnold_012125_PINKYS_2554.webp

Frequent Questions

Studio Steel thermally broken assemblies are NFRC certified and designed to meet 2025 Title 24 Part 6. Nearly every Studio Steel product line has a certified SB70 configuration that qualifies for the prescriptive path in every California climate zone - fixed windows and swing doors both fall into this category when the correct configuration is specified. Casement windows and non-thermally broken solid steel assemblies require the performance path everywhere, since no certified configuration meets the residential prescriptive maximum. Contact PINKYS for project-specific configuration guidance.
The 2025 California Energy Code (Title 24 Part 6), effective January 1, 2026. The prescriptive residential maximum U-factor is 0.27 in most climate zones and 0.30 in Climate Zones 6-10 and 15. SHGC is 0.23 in most zones, not required in Climate Zones 1, 3, 5, and 16, and a stricter 0.20 in Climate Zone 15. This threshold applies to windows and glazed doors alike - Studio Steel swing doors are more than 25% glazed and are classified as glazed doors under the code, not held to the stricter opaque-door standard. Any project with a permit application after January 1, 2026 is subject to the 2025 requirements.
The prescriptive path requires each fenestration product to individually meet climate zone U-factor and SHGC maximums; no whole-building model required. The performance path evaluates the whole building using CEC-approved energy modeling software (CBECC-Res or EnergyPro), allowing tradeoffs between building components. Studio Steel supports both paths with the appropriate product data.
Studio Steel thermally broken casement windows have certified whole-unit U-factors from 0.31 to 0.38 (SB70 configurations). Under the 2025 code, the prescriptive residential maximum is 0.27 in most zones and 0.30 in Climate Zones 6-10 and 15 - casements exceed both thresholds in every zone, even at their best-performing configuration. Casement windows are Performance Only: the whole-building model can accommodate the higher U-factor through compensating measures elsewhere in the envelope. Contact PINKYS at specification stage to discuss the right approach for your project and climate zone.
Yes, with the right configuration. Studio Steel thermally broken swing doors are more than 25% glazed and are classified as glazed doors under Title 24, meaning they're held to the same fenestration threshold as windows (0.27 in most zones, 0.30 in Climate Zones 6-10 and 15), not the stricter 0.20 standard that applies to opaque entry doors. Certified whole-unit U-factors run from 0.26 (triple pane SB70) to 0.35 (dual pane SB70). The triple pane configuration meets the prescriptive maximum in every California climate zone; the dual pane configuration requires the performance path outside Climate Zones 6-10 and 15. Non-thermally broken solid steel swing doors do not meet either threshold and are Performance Only. Contact PINKYS at specification stage to confirm the right configuration for your project's climate zone.
Solid hot-rolled steel assemblies without a thermal break achieve whole-unit U-factors in the range of 0.41-0.74 depending on product and glazing configuration, which exceeds both the 0.27 and 0.30 prescriptive maximums under the 2025 code - Performance Only across the board. These assemblies are appropriate for interior applications, historic restoration projects with code exemptions, and performance path projects where compensating measures in the building envelope accommodate higher-U fenestration. For any exterior application in a conditioned California space on the prescriptive path, thermally broken assemblies are required.
Nonresidential prescriptive fenestration requirements (Table 140.3-B) are generally more permissive than residential on U-factor. Confirmed for the 2025 cycle: fixed windows have a maximum U-factor of 0.34 (Zones 9, 11-15) or 0.36 (all other zones). Operable windows carry a maximum U-factor of 0.46 across all zones, meaning Studio Steel thermally broken casements (U 0.31-0.38) meet nonresidential requirements everywhere despite being Performance Only on the residential path. The nonresidential standard also uses RSHGC rather than SHGC, a related but distinct metric. Confirm current requirements with a licensed Title 24 analyst before permit submittal.
California's 16 climate zones are mapped by the CEC. The online lookup tool accepts address or zip code at energy.ca.gov. Confirm with your Title 24 analyst.
Yes, to alterations and additions as well as new construction, though scope differs from new construction. Consult a licensed Title 24 analyst.
Yes. The NFRC Certified Label ships with every assembly. Additional documentation available on request at specification stage.
closeup of steel window corners showing simulated divided lite and thermal break
new construction featuring installation of large format steel doors with fixed panels

Specify With PINKYS Studio Steel

PINKYS Studio Steel's custom architectural service works with architects and design-build teams from early feasibility through fabrication and installation.

Start your specification

See it before you specify

The PINKYS Los Angeles Flagship is a by-appointment showroom in Vernon, CA, with Studio Steel doors and windows on display. Bring the opening dimensions. Walk the profiles, glazing options, and finishes in person before the specification is final.

Book a showroom appointment
side shot of pinkys showroom steel wall panel
Live Chat
Need help? Ready to buy?
Chat with a PINKYS specialist now!
Call Us 1-844-843-6677
Mon - Fri: 8 AM - 5 PM
Sat: 11 AM - 2 PM
Email Us
Need more info or got a question?
Send us a message!